What you’ll learn

How an AutoCrib LX2000 is set up as a storage device in CRIBWISE: the settings it needs, the modules created for its columns, and how stock locations are defined from the configuration Excel.


Storage device settings

Setting Value
Type Location controlled
Manufacturer AutoCrib LX2000
IP address The IP address of the controller. Default: 192.168.255.2

Module structure

  • Each column is a separate module.
  • 26 modules are created during the first save of the storage device: 3 rotating and 5 static columns on the main platter, plus 9 rotating and 9 static columns on the three small platters.

Stock location structure

  • Locations are created by importing the LX2000 configuration Excel. The same file template is used to update the location structure later.
  • Each column has 15 levels. A location on one level can span several levels above it.
  • Each column on each level can be split into one or more locations of the same size.
  • Levels in rotating columns (01X … 33X) can be split to 1, 1/2, 1/3, 1/4, 1/6 or 1/12 of the full column size, giving 1, 2, 3, 4, 6 or 12 locations on that level.
  • Levels in solid columns (001 … 303) can be split to 1/2 or 1/3 of the full column size, giving 1 or 2 locations on that level.

AutoCrib LX2000 module and location structure in CRIBWISE

Modules and locations as they appear for an LX2000.

Layout of AutoCrib columns and levels

Column and level layout.

Level split into locations of equal size

How a level is split into locations.


Common confusion

People often think… But actually…
Locations are created by hand in CRIBWISE. They come from the LX2000 configuration Excel, and the same template is used for later updates.
All columns can be split the same way. Rotating columns support 1, 1/2, 1/3, 1/4, 1/6 and 1/12 splits; solid columns only 1/2 and 1/3.
One module is created per platter. One module is created per column – 26 in total across the main platter and the three small platters.